Cabin Parts
    Door Hardware, Latches, & Hinges
     Lighting
Heater Parts
     Temperature Selectors & Probes, Probe Amplifiers, & V2F Boards
     Pilot Assemblies - Power Flame & Direct Fire
     Power Flame Burner Parts
     Honeywell Burner Controllers
     Gas Valves and Pressure Regulators
Fans and Motors
     Motor & Light Contactors, Auxiliary Contacts, & Overloads
     Propellers, Blower Wheels, Fans, & Bearings
     Frequency Drives & Phase Converters
Motors:
   Waterwash Intake and Exhaust Motor
Electronic Controls
     Operator Panel Switches and Lights
    Control Relays, Timers, & Transformers
     PLCs & Operator Panels
     Ram Motors, Ram Limit Switches, Rectifiers, & Transformers:
Filtration
    Filters
     Waterwash Parts
Ducting
     Ducting
Miscellaneous
     Airflow Measurement & Control, & Miscellaneous

 

 

Door Hardware, Latches, & Hinges     Back to Top

Model Number   Model Description
DT2RETRO   Kit includes: 2 - 1046LTCH spring-open latches and 1 - DOORPLLS - a pair of 350 lb. rated handles. Service Guide available.
DT1245BC Polished chrome, drive-through (outer) doors #1 and #3 hinge. The OEM brushed chrome finish is no longer available.
DT1246BC   Polished chrome, drive-through (middle) door #2 and personnel door hinge. The OEM brushed chrome finish is no longer available.
NUTSERTS   10 - grade 8, 1/4" threaded nutserts for all hinge bolts, setting tool included.)   NOTE
RODFOLLW   Nylon encased steel rod for the upper half of all hinges.
1245CAM2   Nylon insert socket for the lower half of all hinges.
HEADBOLT   Drive-through door, upper, spring-return bolt with pull chain.
FOOTBOLT   Drive-through door to floor canebolt.   NOTE
1046LTCH   Spring-open, adjustable-tension door latch.
DOORPLLS   A pair of 350 lb. rated door handles and mounting screws.
CNTRMECH   Center Mechanism for the middle drive-through door latch, years 1990 – 1995.
RODBRAKT   A set of four - angled rod brackets for the upper and lower push rods attached to the CNTRMECH.
DOORHNDL   Outside or inside door handle and mounting plate for CNTRMECH.
LIFTLACH   Lift and turn latch for access doors.
DOORSWEP   6 inch by 120 inch, neoprene rubber, drive-through door sweep.   NOTE
WLLLTKEY   Key needed to open wall light door screws.  
DRCLOSER   Hydraulic, industrial duty, 180� opening, personnel door self-closer.   NOTE

 

 

Lighting     Back to Top

Performance Upgrade and Service Guide Available.

The key advantage to upgrading overhead lighting is the lack of a shadow that�s cast by the painter onto the vehicle by wall lights, and the superior lighting of the top surfaces that wall lights can�t illuminate as well. The Service Guide details replacement of the light lenses with tempered glass. Painting requires full spectrum, white light for accurate color matching to noon sunlight. Our Model HALID65K 400 watt halide bulb is the highest rated at 82 CRI and 6,500� K (Kelvin temperature) (sunlight at noon is (100 CRI/6,500� K).

Model Number   Model Description
HALID65K   90 CRI, 6,500K daylight, full spectrum, 400 watt, 28,000 Lumens, 9,000 Hour Life, halide light bulb. One year warranty, two year warranty if used with a 400BLLST. Fits OEM lamps.   NOTE
400BLLST   400 watt electronic ballast, dimmable, instant-on, soft start. Service Guide available. Two year warranty.   NOTE
PWRSUPLY   Eight outlet power supply for 400BLLST lighting upgrade, includes 25 foot of 2 circuit, 12 gauge power wire.
BLSTCORD   10 foot ballast to lamp cord.
1000BLST   1000W Lumatek Digital Ballast. Dual Air Cooled, this 1000W Dual Voltage unit can be powered with 120V or 240V. Ballast comes with 120V power cord but can be upgraded to 240V with additional cost.
20RFLCTR 24 facet, 95% reflective mirror, lamp reflector.

 

 

Temperature Selectors & Probes, Probe Amplifiers, & V2F Boards     Back to Top

Service Guides available.

Model Number   Model Description
HIGHTEMP   High Temperature Limit Switch. Factory set at 125 degrees, remove cover and relocate the dial lock-stop to 205 degrees.
OMRNTEMP Omron temperature selector and controller, 120 VAC. Used on 3220, 4220, and 5220 controls.
E524ACDC   Omron temperature selector and controller, 24V AC or DC. Used on 3220 (upgrade) and BPID controls.
THRMOCPL Thermocouple type temperature probe & PROBEMNT insulated mounting connector. Used with all Omron temperature selectors.   NOTE
RTDPROBE RTD type temperature probe and insulated mounting connector. Used with RTDAMPFR.   NOTE
DUALTHRM Dual digital thermostat conversion for booths with Power Flame burners. Includes temperature probes, Spray or Bake selector, and full installation guide.
RTDAMPFR RTD temperature probe amplifier, also called an SB973, 5218, RTD Board or RTD Transmitter.
V2FOMRON Volt to frequency circuit board for Omron PLCs, also called a V-F PCB, VFv4.0, or 5028.
V2FSMENS   Volt to frequency circuit board for Siemens PLCs, also called a V-F PCB, VFv2.0, or 5176.

 

 

Pilot Assemblies - Power Flame & Direct Fire     Back to Top

Model Number   Model Description
PFFLMROD   Power Flame flame rod.
PFIGNITR   Power Flame ignitor.
2500FR07 Flame rod for 2500, ADDvantage and Performance burners. Freight applies if sold alone.
DFIGNITR   Ignitor for 2500, ADDvantage and Performance burners. Freight applies if sold alone.
PFCABLES Power Flame 18�, silver-tinned, ignitor or flame rod cable, chromed terminals.
DFCABLES   Direct Fire ignitor or flame rod 48" cable, silver-tinned, ignitor or flame rod cable, chromed terminals.
FRPLTREB   Power Flame flame rod type pilot assembly rebuild. Ground rod or pilot case welding repair is $48.00 extra.>
UVPLTREB   Power Flame UV scanner type pilot assembly rebuild. Add $200 for Core charge. 2 Day Freight cost includes prepaid Core return shipping. Overnight OK.
PFUVPILT Power Flame UV scanner type pilot assembly.
PFFRPILT   Power Flame flame rod type pilot assembly.
PILTORIF   Power Flame brass pilot gas orifice.
HWSCANNR   Power Flame UV scanner flame detector.
PLTVLV18   Power Flame 1/8" (3/8" O.D.) (most common size) gas pilot solenoid valve.
PLTVLV14   Power Flame 1/4" (1/2" O.D.) gas pilot solenoid valve.
PLTVLV38   Power Flame 3/8" (5/8" O.D.) gas pilot solenoid valve.
PILOTREG   Power Flame 1/8" pilot gas pressure regulator. Comes with 2 - 1/2" x 1/8" bushings.

 

Power Flame Burner Parts     Back to Top

Model Number   Model Description
PFARSWCH   Power Flame Air Switch.
IGNXFRMR   Power Flame OEM Ignition Transformer.
PFDIFUSR   Power Flame Diffuser.
PFGASKET   Power Flame Flange Gasket.
13PFMOTR   1/3 hp. Blower Motor for a Power Flame JR-30A.
14PFMOTR   1/4hp. 1/2" shaft Blower Motor for a Power Flame JR-15A.   NOTE
12PFWHEL   1/2" shaft Blower Wheel for a JR-15A burner.

 

 

Honeywell Burner Controllers     Back to Top

Model Number   Model Description
HWRM7895   Honeywell burner controller (blue box).   NOTE
HW78BASE   Honeywell burner controller subbase for the HWRM7895.
HW7830SC   Purge Timer plug-in for the HWRM7895.
HWUVAMPL   UV scanner amplifier for the HWRM7895.
HW78FRMP   Flame rod amplifier for the HWRM7895.
HWDIAGNS   Honeywell Diagnostic Module for the HWRM7895.
HWR4795A   Honeywell burner controller (gray box).   NOTE
HW47BASE   Honeywell burner controller subbase for the HWR4795A.
HW4730SC   Purge Timer plug-in for the HWR4795A.   NOTE
HW47FRMP   Flame rod amplifier for the HWR4795A.   NOTE
MICROAMP A full function AMPROBE Digital Multimeter for testing the Honeywell 4795A and 7795B pilot flame microamps.   NOTE

 

 

Gas Valves and Pressure Regulators     Back to Top

Model Number   Model Description
GVBELIMO   Gas valve motor for direct fire burners. NOTE
1AUXGASV   All fuels, on/off, 1" auxiliary gas valve.
1MAINGAS   Natural gas, on/off, 1" main gas valve with regulator.
1MAINLPV   Propane, on/off, 1 1/4" main gas valve with regulator.   NOTE
VNTGSREG   1 1/4" body, positive lock-up, gas regulator, 2 psi in, 7"- 11" pressure out, gas or propane, with vent limiter (no vent line needed).   NOTE
10TO6REG   1 1/4" or 1 1/2" body, 10 psi inlet, lock-up, gas regulator, 3" - 6" outlet pressure, natural gas or propane, vent line required.

 

 

Motor & Light Contactors, Auxiliary Contacts, & Overloads     Back to Top

Service Guides Available.

All contactors and overloads are premium grade Square D and IEC rated.

Model Number   Model Description
3MAG24AC   3220 - R2 Light (magnetic) Contactor, 25 amp, used after July, 1987.
5MAG24AC   5 Hp., 18 amp, motor contactor for 2220 and 3220 controls, comes with an extra Normally Open auxiliary contactor.
75MG24AC   3220 - 7 1/2 Hp., 25 amp, motor contactor.   NOTE
10MG24AC   3220 - 7 1/2 Hp., single phase, 40 amp, 24 VAC coil, motor starter.
2MG120AC   2 Hp. 9 amp, strip-off motor contactor (S97, STD97, and STD98) and 4220 waterwash pump contactor 3C (Furnas Dual PLC version).
3MG120AC   Light (magnetic) Contactor, 25 amp, used on 4220 (2C), 5220 (R2), S97 (M3), STD97 (M3), and STD98 (M3).
75MAG120   7 1/2 Hp. 25 amp motor and light contactor (for 4220, 5220, S97, STD97, and STD98).   NOTE
10MAG120   10 Hp. 32 amp, motor contactor (120 VAC coil for prep station.)
15MAG120   15 Hp., 3 phase, or 7 1/2 Hp., single phase, 40 amp, motor contactor (120 VAC coil for 4220, 5220, S97, STD97, and STD98.)
30MAG120   30 Hp. 80 amp, motor contactor (120 VAC coil)
2MAG24DC   2 Hp. 9 amp, strip-off motor contactor (24 VDC coil used with Siemens 226, 06/02/00 and later.)
5MAG24DC   All LC1 Light (magnetic) Contactors - 32 amps resistive load.
75MG24DC   7 1/2 Hp. 25 amp, 24 VDC coil, motor and light contactor (TD200 ALL24VDC and later SBOP)
AUXCNT11   N.O. + N.C. auxiliary contactor for 5220 exhaust.
AUXCNT20   N.O. + N.O. auxiliary contactor for 3220 intake, 4220 intake & exhaust, and 5220 intake.
12HPOVRL   1/2 Hp. across-the-line, stripoff motor overload (verify OVRMOUNT needed after 0192.)   NOTE
75HPOVRL   5 or 7 1/2 Hp. across-the-line, motor overload (verify OVRMOUNT needed after 0192.)   NOTE
10HPOVRL   10 Hp. across-the-line, motor overload (used with Prep Station.)   NOTE
15HPOVRL   15 Hp. 3 phase, or 7.5 Hp. single phase across-the-line, 40 amp, motor overload.   NOTE
30HPOVRL   30 Hp. across-the-line, motor overload.   NOTE
OVRMOUNT   Mounting kit for 75HPOVR & 10HPOVR overloads.   NOTE

 

 

Propellers, Blower Wheels, Fans, & Bearings     Back to Top

Service Guides Available.

Model Number Model Description
30FNXMTR 30" tubeaxial fan with a 3075PROP propeller, no motor or belts.
3050PROP 30" propeller for a 5 hp. Motor, lifetime warranty. Factory ready-to-ship is 10 days. Add $99.35 for same day ready-to-ship expediting.
3075PROP 30" propeller for a 7.5 hp. Motor, lifetime warranty. Factory ready-to-ship is 10 days. Add $99.35 for same day ready-to-ship expediting.
3475PROP 34" propeller for a 7.5 hp. Motor, lifetime warranty. Factory ready-to-ship is 10 days. Add $64.33 for 5 day ready-to-ship expediting.   NOTE
ADDBRNG7 A pair of 1-7/16", 210° F., pillow-block, shaft bearings, eccentric-lock shaft collar.   NOTE
ADDBRNG3 A pair of 1-3/16", 210° F., pillow-block, shaft bearings, eccentric-lock shaft collar.   NOTE
ADDSHFT3 1-7/16" diameter shaft x 36", full length keyway for ADDvantage intake blowers.    NOTE
ADDSHFT4 1-7/16" diameter shaft x 48", full length keyway for ADDvantage exhaust blowers.
ADDSHFT5 1-7/16" diameter shaft x 60", full length keyway for Prep Stations.  
MXRMFN10 Mix Room intake or exhaust fan, 115 volt motor and blower. This economical OEM replacement easily delivers required airflows - 450 CFM at .5" SP.   NOTE
MXRMFN30 Mix Room intake or exhaust fan, 230 volt (two pole) motor conversion from 3 phase. This economical OEM replacement easily delivers required airflows - 450 CFM at .5" SP.   NOTE
MXRMFNOE   OEM direct replacement Mix Room intake or exhaust fan used through 1998, 115 or 230 volt. Deliver 1,100 CFM @ .5" SP.   NOTE
STRIPOFF   Stripoff fan, 230 volt (two pole) motor conversion from 3 phase. Delivers 775 CFM at .5" SP.   NOTE
12CWWEEL   Mix Room or Stripoff fan blower wheel, clockwise rotation (sitting on the motor, facing the shaft end), 1/2" shaft that can be drilled out for a 5/8" shaft.
25BLOWER   Reverse-inclined, direct-drive, blower wheel for the Model 2500 AMU.   NOTE
DVFNBRNG   DeVilbiss fan bearing and shaft assembly.

 

 

Frequency Drives & Phase Converters     Back to Top

Service Guides Available.

Frequency Drives change motor speed to accurately control exhaust air flow and save electricity wasted pushing air past the damper. They �soft start� motors to full speed in 10-15 seconds, greatly extending motor life. Their overload shutdown monitors all three phases separately.

On both Spraybake manual and automatic exhaust damper systems, if the exhaust is not cleaned regularly, the cabin will go very positive causing the Belimo damper motor to be constantly powered, burning it out. With a frequency drive, the exhaust damper and Belimo damper motor are no longer needed.

Frequency drives can also convert single phase to three phase.

There are two kinds of drives: the cheaper, more common volts/hertz type, and the vector type.

The volts/hertz type discharges power based on a sensor monitoring the motor demand. They�re about 10% cheaper but give off increasingly distorted power when used below 40% speed, causing motor heating and likely will trip out below 20%. This drive should only be used for exhaust boxes and prep stations.

The sensorless vector�s microprocessor exactly matches voltage and amperage to frequency, giving full and precisely matched power down to 20% speed, and full power down to 1% for a few minutes. Vector types last much longer and are far easier on motors used below 50%. This drive is ideal for spray booth motors that, in bake, run at 15-20% speed.

Model Number   Model Description
3FREQ323   3 hp. vector frequency drive, 3 phase, 208/240 Volt input.
5FREQ323   5 hp. vector frequency drive, 3 phase, 208/240 Volt input.
5FREQ123 5 hp. vector frequency drive, single phase, 220/240 Volt input.
75FRQ323   7-1/2 hp. vector type frequency drive, 3 phase, specify 208/240 or 400/480 Volt input. Programming and Installation Guide provided.
75FRQ123   7-1/2 hp. vector frequency drive, single phase input, three phase output with motor speed control. Installation guide provided.
10FRQ323   10 hp. vector frequency drive, 3 phase, 208/240 Volt input.
10FRQ123   10 hp. vector frequency drive, single phase, 220/240 Volt input.
15FRQ323   15 hp. vector frequency drive, 3 phase, 480 Volt input.
SMENS420   Siemens 420 Micromaster 7 1/2 hp. frequency drive, 3 phase, 208/240 Volt input, 2 year warranty. Full warranty factory refurbs may be available for less.
SMENSBOP   Keypad and screen operator panel for the Siemens 420 and 440 frequency drives.
FRQKYPAD   Remote operator display and keypad for all frequency drives.   NOTE

 

 

Waterwash Intake and Exhaust Motor     Back to Top

Removal and Replacement Guides Available.

Waterwash Intake and Exhaust Motors:

The OEM motor had custom 60" wire leads and is unavailable. New motors have a junction box too large for the fan housing. We provide a low profile junction box and 60" cord. We also provide 12 - grade 8, yellow-zinc flange bolts with nuts and washers, weatherproof wire nuts, and a cord connector.The OEM motor ran too hot. Our motor's narrow body allows twice as much air cooling. Our motor has an end-thrust bearing at the shaft end, needed for vertical mount motors. We also provide a Motor Replacement Guide.
 

Model Number   Model Description
75WWMTR2   7 1/2 hp. slim body, flanged motor. Low profile wire box & 60" cord shipped separately for assembly onsite. Will-call local pickup or Next Day Ship available.   NOTE
5WWODMTR   5 Hp., flanged face, end-thrust bearing, twin cooling fan, exhaust motor.   NOTE
75ODPMTR   7 1/2 Hp., open drip proof ODP, ADDvantage or DeVilbiss (intake only) motor, footed base only, 125% Safety Factor.   NOTE
5ODPMTR   5 Hp., Performance or DeVilbiss exhaust motor, premium efficient, inverter duty, 125% Safety Factor.   NOTE
75TFCFLG   7 1/2 Hp., wet or dusty environment, TEFC, Performance/2500 intake or exhaust motor, cast iron, C-face, 125% Service Factor.   NOTE
75TFCFTD   7 1/2 Hp., wet or dusty environment, TEFC, ADDvantage or DeVilbiss motors, cast iron, footed base only, 125% Service Factor.
1GRVPULY   1-groove, adjustable belt diameter pulley for a 7� Hp. ADDvantage intake or exhaust motor.   NOTE
2GRVPULY   2-groove, 5.24" to 6.45"adjustable diameter pulley, 7 1/2 Hp. motors, 1 3/8" shaft, 5L, B, or BX belts, 5/16" x 5/16" key.   NOTE

 

 

Operator Panel Switches and Lights     Back to Top

Model Number   Model Description
SB2220SW   Spray or Bake switch, 2220 or SB-E wiring diagrams, NEMA 4X outdoor rated.
SB3220SW   Spray or Bake switch, 88-3220E (NO+NO+NC) or 86-3220E (NO+NO) wiring diagrams, NEMA 4X outdoor rated.
SB4220SW   Spray or Bake switch, 4220 wiring diagrams, NEMA 4X outdoor rated.
322LIGHT   2220 and 3220 Light ON/Off Switch and 2220 Spray/Bake switch, , NEMA 4X outdoor rated, comes with extended lever.
422LIGHT   4220, Light Switch with OFF/ON nameplate.   NOTE
3220STOP   2220 and 3220, red, non-lighted, push-button Stop Switch.
322START   2220 and 3220, green, non-lighted, push-button Start Switch.
3220BULB   24 volt AC, LED indicator light bulb.   NOTE
3220LAMP   Pilot Light complete, 24 volt AC, LED bulb, red, yellow or green lens.
4220STOP   4220 red, push-button, lighted Stop Switch.
422START   4220 green, push-button, lighted Start Switch.
4220BULB   120 volt AC, Start/Stop button, LED bulb.   NOTE
422GRLED   12 volt DC, green LED panel door light.
422RDLED   12 volt DC, red, LED panel door light.
EMERSTOP   Push-pull emergency stop button and nameplate.
NOCONTCT   N.O. (Normally Open) contact block for all Start, Stop, and Emergency Stop switches.
PUFFSWCH   A pair of Prep Station air-button "puff" switches.
PNLONOFF   Master Disconnect Switch for Control Panels, 3 Phase, 80 amps, with handle and shaft for panel door mount, OEM.

 

 

Control Relays, Timers, & Transformers     Back to Top

Model Number   Model Description
LIGHTRLY   2220 & 3220 - R1 (Burner relay) or R2 (optional Light relay) or R3, R3A and R4 Ram relays - 16 amp, silver contacts, comes with socket base (11PNSOCK).   NOTE
322BKTMR   2220 & 3220 - TR1 Bake Timer relay, comes with mounting adapter and socket base.   NOTE
TR2ORTR3   2220 and 3220 - TR2 timer relay (5 minute Cool Down) or TR3 timer relay (3 minute Purge).
RAMTIMER   2220 & 3220 - TR4 or TR5 Ram Motor Timer relays (set both for 15 seconds), comes with new socket base (8PNSOCKT).
422BKTMR   0 to 60 minute bake timer and mounting adapter.
3PRLY120   4220 Relays - TCR, CRT, CR, 1C, F/RAM, R/RAM - 16 amp, silver contact, 11 pin, comes with 11PNSOCK socket.
DPRLY120   S97 Relays RL4 and RL5. Includes new socket base and added LED on-indicator.
SPRLY120   All Relays RL1, RL2, RL3, and RL7. S97 RL6 and RL8. STD97 Relay 8. All Relays CR3 and CR4. Siemens 2D and 2/3Kx Relays CR7 and CR8. Siemens 2P Relays CR5 and CR6. Includes new socket base and LED on-indicator.
DPRLY24D   STD97 and STD98 Relays RL4 and RL5. All CR6 Relays (except Siemens 2P). All MCR Relays. Siemens 2P Relay CR8. Includes new socket base and added LED on-indicator.
SPRLY24D   STD97 and STD98 Relays RL6, RL9, RL10, and RL11. All Relays CR1 and CR2. All CR5 Relays (except Siemens 2P). Siemens 2I and 2P Relay CR7. Siemens 2/3Kx Relay CR9. Includes new socket base and added LED on-indicator.
11PNSOCK   4220 - Upgraded 11 pin, 16 amp, relay socket. The OEM Electromatic S411 socket was only 10 amp rated and should be replaced.
11PNR1R2   3220 OEM and Alternate 4220 - 11 pin, 15 amp, "round" style relay socket.
350VATRN   Control & Ram Motor Transformer, 240 VAC to 12 & 24 VAC, 350VA (3220 wiring).
150VATRN   Ram Motor Transformer, 120 VAC to 12 VAC, 150 VA (4220, 5220, S97, STD97, STD98, TF2, TF3, TXF1, and TXF2)
2402120X   Transformer, 240 VAC to 120 VAC, 350VA (SBOP wiring).

 

 

PLCs & Operator Panels     Back to Top

Model Number   Model Description
4220CLCK   4220 controls - replacement PLC (Programmable Logic Controller) (January, 1992 to April, 1997) with upgraded features.   NOTE
S97CPM1A   Replacement Omron CPM1A (February, 1997 to September, 1998) with upgraded S97 software.   NOTE
S97NT11S   S97 Omron NT11S operator panel (February, 1997 � September, 1998.)
9XCOMCBL   9 conductor, 24 gauge tinned, communication cable, shielded, with drain wire.)
STD97PLC   Replacement STD97 Siemens PLC (October, 1998 to January, 1999.)
24VDCPWR   120 VAC to 24 VDC Power Supply for all Siemens PLC's
8X10X4BX   Operator panel enclosure and interior mounting panel for S97NT11S.   NOTE
CPMNTRFC   Communication interface module for the S97 PLC.
TD200PNL   TD200 operator panel for the STD97 and STD98 operating systems.
TD200DB9   DB9 wire harness for the TD200 operator panel.   NOTE
SBOPRTRO   SBOP retrofit PLC, operator panel, communication module, temperature controls, cabin pressure gauge and controls. Full installation and wiring guide provided.
SBOPDCAL   #5648 replacement decal for the SBOPPANL that includes new touch-key pads.

 

 

Ram Motors, Ram Limit Switches, Rectifiers, & Transformers:     Back to Top

Model Number   Model Description
D12X8RAM   Electric ram motor for 1000 style (waterwash) booth.
ADDVRAM4   Electric ram motor for ADDvantage booths. This upgraded ram motor has 112 foot-lbs. of torque instead of the OEM 75 foot-lbs.
PERFRAM6   Electric ram motor for Performance style booth.
ADDAIRRM   4� air cylinder ram for ADDvantage style booth.
WWAIRRM8   8�, air cylinder ram for 1000 series booth.   NOTE
AIRVLV24   Ram Air Valve and 24 VAC coil - 3220 controls.
ARVLV120   Ram Air Valve and 120 VAC coil - 5220 controls.
XMUFFLER   1/8" NPT, Exhaust Muffler for AIRVLV24 and ARVLV120
FLTRGOIL   Combination compressed air filter, pressure regulator and oiler for ADDAIRRM and WWAIRRM8.
150VATRN   Ram transformer, 120 VAC to 12 VAC, 150VA, 4220 & newer wiring.
350VATRN   3220 TX1 Transformer, 120 VAC to 24 and 12 VAC.
RAMLMTSW   Ram limit switch (LS1.)
5324RECT   BR1 bridge rectifier that converts AC to DC for the ram motor.   NOTE
24VDCPWR   Power Supply Unit (PSU) converts 120 VAC to 24 VDC for the Siemens PLC.

 

 

Filters     Back to Top

Model Number   Model Description
3026MAIN   78 3/4" x 246" OEM (full thickness) Viledon Ceiling Filter (fresh with tacky glue.)
50X252MN   50" x 252" OEM (full thickness) Viledon Ceiling Filter for 14' x 24' ADDvantage Booths, (fresh with tacky glue). Pack of 2 (full change out).
39X292MN   39" x 292" OEM (full thickness) Viledon Ceiling Filter for 14' x 25' ADDvantage 2000 Series Booths, (fresh with tacky glue). Pack of 3 (full change out).
3026X360   78 3/4" x 360" OEM (full thickness) Viledon Ceiling Filter (fresh with tacky glue.)
81X145MN   81" x 145" OEM (full thickness) Viledon Ceiling Filter for Blowtherm booths, (fresh with tacky glue). Pack of 2 (full change out).
60X312MN   60" x 312" OEM (full thickness) Viledon Ceiling Filter for Performance Booths, (fresh with tacky glue). Pack of 2 (full change out).
60X342MN   60" x 342" OEM (full thickness) Viledon Ceiling Filter for 28 Foot Performance Booths, (fresh with tacky glue). Pack of 2 (full change out).
37X70PRP   Case of 6 - 37" x 70" OEM (full thickness) Viledon Ceiling Filter (fresh with tacky glue.)
61X150CF   Case of 4 - 61 x 150 (DeVilbiss) Viledon Ceiling Filters (fresh with tacky glue.)
38X107MN   CCase of 7 - 38" x 107" Garmat Viledon Ceiling Filters (fresh with tacky glue).
30275053   Case of 6 - 50 x 53 (oversized) Water Wash Pads.
30272148   Case of 12 - 21 x 47.5 (oversized) Water Wash Side Pads.
30274040   Case of 8 - 40 x 40 Water Wash Pads.
302830BG   30" Prefilter Bag.
302824BG   24" Prefilter Bag.
6532POCK   Case of 8 - 20"x24"x21" deep, 2-Pocket, Double Prep, Exhaust V-filters.
20X40PRE   Case of 4 (1 change out), 20" x 40" (2 x 20" links) Bananaza B-1000 Prefilters.
25X72PRE   Case of 10 (5 change outs), 25" x 72" (4 x 18" links) Weather-Rite Prefilters.
36X300FG   2.5" thick x 36" wide x 300' roll of fiberglass (with a polyester backing layer) exhaust filter.
302432PT   32" wide x 65' roll (2 - 5'x16' pit change outs), "Paint Pocket" type Pit Filter.   NOTE

 

 

Waterwash Parts     Back to Top

Model Number   Model Description
WWPMPMTR   Waterwash pump motor, includes new pump seal.
WWHAYPMP   Waterwash Pump and Motor.
SUMPPUMP   OEM waterwash, cast iron, 0.4 Hp. sump pump
PMPHOSES   Retrofit suction and discharge hoses, quick-connects and fittings for the waterwash pump.
48WWRACK   Upgraded waterwash nozzle rack kit for 48" wide waterwash tanks.   NOTE
38WWRACK   Upgraded waterwash nozzle rack kit for 38" wide waterwash tanks.   NOTE
WWPICKUP   Intake Pickup Tube, Check Valve, Hose & Fittings.   NOTE
WALLFLNG   2 flanged penetrations through the waterwash tank & fasteners.   NOTE
FLOATVLV   Brass wash tank valve, rod, and reinforced copper float ball.
STRAINER   Waterwash pump strainer basket.
IMPELLER   Waterwash pump impeller.
WWCHECKV   Waterwash tank 1�� intake pickup tube check valve.
PUMPSEAL   Waterwash pump seal.
SEALPLTE   Waterwash pump seal plate.
H2OREDCR   Water pressure reducing valve.   NOTE
FLOATBLL   Copper float ball, reinforced at the rod connection, and rod.
WWNOZZLE   Waterwash spray ball-nozzle and clamp-on base assembly.
13NZZLES   13 replacement ball nozzles.

 

 

Ducting     Back to Top

Many Duct Routing Plans Available

Model Number   Model Description
30DAMPER   30� Weather-cap and Damper.
2430DOOR   24� x 24�, 20 gauge access door, rolled to a 30" diameter.
30DCTFLG   30� inside diameter, 18 gauge duct flange.
30CMPFLG   A pair of 30�� inside diameter, 14 gauge, Dayton duct flange.

 

 

Airflow Measurement & Control, & Miscellaneous     Back to Top

Model Number   Model Description
FANAIRSW   Fan air flow switch. Installation and service guide available.
EXDOORSW   Hazardous location door switch.
AIRSOLND   Air solenoid valve (without coil).
120VCOIL   120 VAC coil for the AIRSOLND.
ANEMOMTR   Air speed and temperature gauge, with a max air speed feature.
25MGNHLC   0 - 0.25" (Water Column) magnehelic air pressure gauge.   NOTE
10MGNHLC   0 - 10" (Water Column) magnehelic air pressure gauge.   NOTE
10INGAGE   0 - 10" (Water Column) gas pressure gauge, 1/4" NPT port.
MANOMETR   Manometer air pressure gauge.
CABLKNOB   Micro-adjust knob for the exhaust damper cable.
DMPRCABL   9�-6� cable and CABLKNOB to control the exhaust damper.
DMPRMOTR   Exhaust damper motor.
TRANSDCR   ± 0.1", 24 VDC, 0-5 VDC, Setra pressure transducer.   NOTE
AIRMOTOR   Rotary air motor for a DeVilbiss exhaust damper.
GRADVALV   Increasing air (gradual) valve to control a DeVilbiss exhaust damper AIRMOTOR.
DAMPRACT   DeVilbiss damper actuator with end switch, 120 VAC (call for availability.)
3M56WRAP   56" x 300" roll of 3M "DIRT TRAP" white, adhesive-backed, wall & floor paper.   NOTE
3026KNOB   Ceiling Filter threaded knob. Verify 5/16-18 (coarse) or 5/16-24 (fine) threads.
3026WIRE   Ceiling filter support wire (spring-loaded).

 